{"id":2914,"date":"2025-12-05T08:07:45","date_gmt":"2025-12-05T07:07:45","guid":{"rendered":"https:\/\/www.herz-energie.at\/en\/?page_id=2914"},"modified":"2026-02-11T15:58:19","modified_gmt":"2026-02-11T14:58:19","slug":"herz-biofire-2000-taurus","status":"publish","type":"page","link":"http:\/\/www.herz-energie.at\/en\/products\/wood-chip-pellet-boiler\/herz-biofire-2000-taurus\/","title":{"rendered":"HERZ BioFire Taurus 2000"},"content":{"rendered":"<p><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 has-pattern-background has-mask-background fusion-parallax-none nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-background-position:left center;--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-padding-top:166px;--awb-padding-bottom:40px;--awb-margin-top:-130px;--awb-background-image:url(&quot;https:\/\/www.herz-energie.at\/wp-content\/uploads\/2019\/05\/pellets-hackgut-feuer-Pelletskessel_neu-e1557829811190.jpg&quot;);--awb-background-size:cover;\" ><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_3_5 3_5 fusion-three-fifth fusion-column-first\" style=\"--awb-padding-top:10px;--awb-padding-left:15px;--awb-overflow:hidden;--awb-bg-color:rgba(0,102,65,0.97);--awb-bg-blend:overlay;--awb-bg-size:cover;--awb-box-shadow:-20px 0px 0px #004f38;;--awb-border-color:#ffffff;--awb-border-top:0;--awb-border-right:0;--awb-border-bottom:0;--awb-border-left:0;--awb-border-style:solid;--awb-border-radius:0px 20px 20px 0px;--awb-margin-bottom:-100px;width:60%;width:calc(60% - ( ( 4% ) * 0.6 ) );margin-right: 4%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-text fusion-text-1\"><h1 class=\"ai-optimize-7\"><span style=\"color: #ffffff;\">Wood chip-pellet boiler<\/span><br \/>\n<span style=\"color: #ffffff;\">BioFire <\/span><span style=\"color: #ffffff;\">Taurus <\/span><span style=\"color: #ffffff;\">2000 <\/span><\/h1>\n<h4 class=\"ai-optimize-8\"><span style=\"color: #ffffff; text-align: left;\"><em>Power range 2000 kW <\/em><\/span><i class=\"fb-icon-element-1 fb-icon-element fontawesome-icon fa-industry fas circle-no fusion-text-flow\" style=\"--awb-font-size:24px;--awb-margin-right:12px;\"><\/i><i class=\"fb-icon-element-2 fb-icon-element fontawesome-icon fa-city fas circle-no fusion-text-flow\" style=\"--awb-font-size:24px;--awb-margin-right:12px;\"><\/i><\/h4>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_1_3 1_3 fusion-one-third fusion-column-last\" style=\"--awb-bg-blend:overlay;--awb-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% ) * 0.33333333333333 ) );\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-2 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;\" ><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_3_5 3_5 fusion-three-fifth fusion-column-first\" style=\"--awb-padding-top:10px;--awb-padding-right:10px;--awb-padding-bottom:10px;--awb-padding-left:10px;--awb-bg-position:right bottom;--awb-bg-blend:overlay;--awb-bg-size:cover;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-sep-clear\"><\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"margin-left: auto;margin-right: auto;margin-top:70px;width:100%;\"><\/div><div class=\"fusion-sep-clear\"><\/div><div class=\"fusion-text fusion-text-2\"><p class=\"ai-optimize-105\">The BioFire 2000 Taurus is an impressive industrial version of the tried-and-tested wood chip pellet system \u2013 for reliable continuous operation and maximum efficiency.<\/p>\n<h3 class=\"ai-optimize-10\" style=\"margin-bottom: 0px; text-align: left;\" data-fontsize=\"26\" data-lineheight=\"44\">The HERZ BioFire Taurus 2000 \u2013 individually applicable&#8230;<\/h3>\n<p class=\"ai-optimize-11\"><ul style=\"--awb-iconcolor:#e10707;--awb-line-height:23.8px;--awb-icon-width:23.8px;--awb-icon-height:23.8px;--awb-icon-margin:9.8px;--awb-content-margin:33.6px;\" class=\"fusion-checklist fusion-checklist-1 fusion-checklist-default type-icons\"><li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa-building fas\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\"><\/p>\n<p class=\"ai-optimize-12\"><span style=\"color: #004f38;\"><strong>Large buildings<\/strong><\/span><br \/>\nsuch as hospitals, schools and public buildings &#8230;<\/div><\/li><li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa-home fas\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">\n<span style=\"color: #004f38;\"><b>Settlement projects<br \/>\n<\/b><\/span>for heating neighbourhoods, residential complexes, etc.<\/div><\/li><li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa-industry fas\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">\n<span style=\"color: #004f38;\"><strong>Industrial companies &amp; process heat<br \/>\n<\/strong><\/span><\/div><\/li><\/ul><\/p>\n<\/div><div class=\"fusion-sep-clear\"><\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"margin-left: auto;margin-right: auto;margin-bottom:30px;width:100%;\"><\/div><div class=\"fusion-sep-clear\"><\/div><div class=\"fusion-content-boxes content-boxes columns row fusion-columns-3 fusion-columns-total-3 fusion-content-boxes-1 content-boxes-icon-with-title content-left\" style=\"--awb-margin-bottom:-20px;--awb-hover-accent-color:#e10707;--awb-circle-hover-accent-color:#e10707;\" data-animationOffset=\"top-into-view\"><div style=\"--awb-backgroundcolor:rgba(255,255,255,0);\" class=\"fusion-column content-box-column content-box-column content-box-column-1 col-lg-4 col-md-4 col-sm-4 fusion-content-box-hover content-box-column-first-in-row\"><div class=\"col content-box-wrapper content-wrapper link-area-link-icon link-type-text icon-hover-animation-pulsate\" data-animationOffset=\"top-into-view\"><div class=\"heading heading-with-icon icon-left\"><a class=\"heading-link\" style=\"float:left;\" href=\"https:\/\/www.herz-energie.at\/en\/downloads-2\/?drawer=Prospekte%20=%20Brochures*English%20=%20Englisch\" target=\"_blank\" rel=\"noopener noreferrer\"><div class=\"icon\"><i style=\"border-color:rgba(255,255,255,0);border-width:0px;background-color:rgba(225,7,7,0.9);box-sizing:content-box;height:42px;width:42px;line-height:42px;border-radius:50%;font-size:21px;\" aria-hidden=\"true\" class=\"fontawesome-icon fa-file-pdf far circle-yes\"><\/i><\/div><h2 class=\"content-box-heading\" style=\"--h2_typography-font-size:18px;line-height:23px;\">Brochure Download<\/h2><\/a><\/div><\/div><\/div><div style=\"--awb-backgroundcolor:rgba(255,255,255,0);\" class=\"fusion-column content-box-column content-box-column content-box-column-2 col-lg-4 col-md-4 col-sm-4 fusion-content-box-hover \"><div class=\"col content-box-wrapper content-wrapper link-area-link-icon link-type-text icon-hover-animation-pulsate\" data-animationOffset=\"top-into-view\"><div class=\"heading heading-with-icon icon-left\"><a class=\"heading-link\" style=\"float:left;\" href=\"https:\/\/www.herz-energie.at\/en\/products\/storage-and-transport-systems\/\" target=\"_blank\" rel=\"noopener noreferrer\"><div class=\"icon\"><i style=\"border-color:rgba(255,255,255,0);border-width:0px;background-color:rgba(225,7,7,0.9);box-sizing:content-box;height:42px;width:42px;line-height:42px;border-radius:50%;font-size:21px;\" aria-hidden=\"true\" class=\"fontawesome-icon fa-houzz fab circle-yes\"><\/i><\/div><h2 class=\"content-box-heading\" style=\"--h2_typography-font-size:18px;line-height:23px;\">Storage- and transport systems<\/h2><\/a><\/div><\/div><\/div><div style=\"--awb-backgroundcolor:rgba(255,255,255,0);\" class=\"fusion-column content-box-column content-box-column content-box-column-3 col-lg-4 col-md-4 col-sm-4 fusion-content-box-hover content-box-column-last content-box-column-last-in-row\"><div class=\"col content-box-wrapper content-wrapper link-area-link-icon link-type-text icon-hover-animation-pulsate\" data-animationOffset=\"top-into-view\"><div class=\"heading heading-with-icon icon-left\"><a class=\"heading-link\" style=\"float:left;\" href=\"https:\/\/www.herz-energie.at\/en\/product-inquiry\/\" target=\"_blank\" rel=\"noopener noreferrer\"><div class=\"icon\"><i style=\"border-color:rgba(255,255,255,0);border-width:0px;background-color:rgba(225,7,7,0.9);box-sizing:content-box;height:42px;width:42px;line-height:42px;border-radius:50%;font-size:21px;\" aria-hidden=\"true\" class=\"fontawesome-icon fa-envelope-open far circle-yes\"><\/i><\/div><h2 class=\"content-box-heading\" style=\"--h2_typography-font-size:18px;line-height:23px;\">Request now<\/h2><\/a><\/div><\/div><\/div><div class=\"fusion-clearfix\"><\/div><\/div><div class=\"fusion-text fusion-text-3\" style=\"--awb-text-transform:none;\"><p class=\"ai-optimize-107\"><a href=\"https:\/\/www.herz-energie.at\/dokumentationen\/\" target=\"_blank\" rel=\"noopener\"><div class=\"fusion-fa-align-left\"><i class=\"fb-icon-element-3 fb-icon-element fontawesome-icon fa-download fas circle-no\" style=\"--awb-iconcolor:#e41f1f;--awb-font-size:16px;--awb-margin-right:8px;\"><\/i><\/div>Product information (PDF)<\/a><\/p>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-3 fusion_builder_column_2_5 2_5 fusion-two-fifth fusion-column-last\" style=\"--awb-bg-blend:overlay;--awb-bg-size:cover;--awb-border-color:#dddddd;--awb-border-top:0;--awb-border-right:0;--awb-border-bottom:0;--awb-border-left:0;--awb-border-style:solid;--awb-margin-bottom:20px;width:37.6%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-sep-clear\"><\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"margin-left: auto;margin-right: auto;margin-top:20px;width:100%;\"><\/div><div class=\"fusion-sep-clear\"><\/div><div class=\"fusion-slider-sc fusion-flexslider-loading flexslider flexslider-hover-type-none\" data-slideshow_autoplay=\"1\" data-slideshow_smooth_height=\"0\" data-slideshow_speed=\"7000\" style=\"max-width:100%;height:100%;\"><ul class=\"slides\"><li class=\"image\"><a class=\"lightbox-enabled\" data-rel=\"iLightbox[slider_carousel_1]\" href=\"https:\/\/www.herz-energie.at\/wp-content\/uploads\/2025\/10\/Links-bot_BioFire-2000_front_Sch.png\" target=\"_self\"><span class=\"fusion-image-hover-element hover-type-none\"><img decoding=\"async\" src=\"https:\/\/www.herz-energie.at\/wp-content\/uploads\/2025\/10\/Links-bot_BioFire-2000_front_Sch-300x300.png\" class=\"wp-image-24458\" \/><\/span><\/a><\/li><li class=\"image\"><a class=\"lightbox-enabled\" data-rel=\"iLightbox[slider_carousel_1]\" href=\"BioFIre_2000_Taurus_Schnittbild\" target=\"_self\"><span class=\"fusion-image-hover-element hover-type-none\"><img decoding=\"async\" src=\"https:\/\/www.herz-energie.at\/wp-content\/uploads\/2025\/11\/BioFIre_2000_Taurus_Schnittbild-286x300.png\" class=\"wp-image-24892\" \/><\/span><\/a><\/li><\/ul><\/div><div class=\"fusion-sep-clear\"><\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"margin-left: auto;margin-right: auto;margin-bottom:-80px;width:100%;\"><\/div><div class=\"fusion-sep-clear\"><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-3 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-margin-bottom:-20px;--awb-background-color:#ebebec;\" ><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-4 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\" style=\"--awb-bg-blend:overlay;--awb-bg-size:cover;--awb-margin-top:20px;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-text fusion-text-4\"><h2 class=\"ai-optimize-13\" style=\"margin-bottom: 0px; text-align: left;\" data-fontsize=\"26\" data-lineheight=\"44\"><span style=\"color: #004f38;\"><i class=\"fb-icon-element-4 fb-icon-element fontawesome-icon fa-check-double fas circle-yes fusion-text-flow\" style=\"--awb-circlecolor:#ed1d24;--awb-circlecolor-hover:#ed1d24;--awb-circlebordercolor:#ed1d24;--awb-circlebordercolor-hover:#ed1d24;--awb-circlebordersize:1px;--awb-font-size:17.6px;--awb-width:35.2px;--awb-height:35.2px;--awb-line-height:33.2px;--awb-margin-right:10px;\"><\/i>The great advantages of the HERZ BioFire Taurus 2000<\/span><\/h2>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-4 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-sizes-top:0px;--awb-border-sizes-bottom:0px;--awb-border-sizes-left:0px;--awb-border-sizes-right:0px;--awb-border-color:#ffffff;--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-margin-top:20px;--awb-margin-bottom:-20px;--awb-background-color:#ebebec;\" ><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-5 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\" style=\"--awb-bg-blend:overlay;--awb-bg-size:cover;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-tabs fusion-tabs-1 classic vertical-tabs icon-position-left mobile-mode-accordion\" style=\"--awb-title-border-radius-top-left:0px;--awb-title-border-radius-top-right:0px;--awb-title-border-radius-bottom-right:0px;--awb-title-border-radius-bottom-left:0px;--awb-alignment:start;--awb-inactive-color:#dddddd;--awb-background-color:#ffffff;--awb-border-color:#ebeaea;--awb-active-border-color:#006641;\"><div class=\"nav\"><ul class=\"nav-tabs\" role=\"tablist\"><li class=\"active\" role=\"presentation\"><a class=\"tab-link\" data-toggle=\"tab\" role=\"tab\" aria-controls=\"tab-874d6c5e9186f94958d\" aria-selected=\"true\" id=\"fusion-tab-1.combustionchamber\" href=\"#tab-874d6c5e9186f94958d\"><h4 class=\"fusion-tab-heading\">1. COMBUSTION CHAMBER<\/h4><\/a><\/li><li role=\"presentation\"><a class=\"tab-link\" data-toggle=\"tab\" role=\"tab\" aria-controls=\"tab-246bb97691b3ec6137e\" aria-selected=\"false\" tabindex=\"-1\" id=\"fusion-tab-2.fluegasrecirculation\" href=\"#tab-246bb97691b3ec6137e\"><h4 class=\"fusion-tab-heading\">2. FLUE GAS RECIRCULATION<\/h4><\/a><\/li><li role=\"presentation\"><a class=\"tab-link\" data-toggle=\"tab\" role=\"tab\" aria-controls=\"tab-4330ef8f3392df8328a\" aria-selected=\"false\" tabindex=\"-1\" id=\"fusion-tab-3.automaticcompressedaircleaning\" href=\"#tab-4330ef8f3392df8328a\"><h4 class=\"fusion-tab-heading\">3. AUTOMATIC COMPRESSED AIR CLEANING<\/h4><\/a><\/li><li role=\"presentation\"><a class=\"tab-link\" data-toggle=\"tab\" role=\"tab\" aria-controls=\"tab-98794b8bd28b1840c6d\" aria-selected=\"false\" tabindex=\"-1\" id=\"fusion-tab-4.power&amp;combustioncontrolcvp\" href=\"#tab-98794b8bd28b1840c6d\"><h4 class=\"fusion-tab-heading\">4. POWER &amp; COMBUSTION CONTROL CVP<\/h4><\/a><\/li><li role=\"presentation\"><a class=\"tab-link\" data-toggle=\"tab\" role=\"tab\" aria-controls=\"tab-e630d6ef2108649200a\" aria-selected=\"false\" tabindex=\"-1\" id=\"fusion-tab-5.feeding\" href=\"#tab-e630d6ef2108649200a\"><h4 class=\"fusion-tab-heading\">5. FEEDING<\/h4><\/a><\/li><li role=\"presentation\"><a class=\"tab-link\" data-toggle=\"tab\" role=\"tab\" aria-controls=\"tab-2ccbaa6d3134603a5ed\" aria-selected=\"false\" tabindex=\"-1\" id=\"fusion-tab-6.optional:hilovesystem\" href=\"#tab-2ccbaa6d3134603a5ed\"><h4 class=\"fusion-tab-heading\">6. OPTIONAL: HILOVE SYSTEM<\/h4><\/a><\/li><li role=\"presentation\"><a class=\"tab-link\" data-toggle=\"tab\" role=\"tab\" aria-controls=\"tab-ba54cbd1f13e3fbf502\" aria-selected=\"false\" tabindex=\"-1\" id=\"fusion-tab-7.optionalluwa-system\" href=\"#tab-ba54cbd1f13e3fbf502\"><h4 class=\"fusion-tab-heading\">7. OPTIONAL LUWA-SYSTEM<\/h4><\/a><\/li><\/ul><\/div><div class=\"tab-content\"><div class=\"nav fusion-mobile-tab-nav\"><ul class=\"nav-tabs\" role=\"tablist\"><li class=\"active\" role=\"presentation\"><a class=\"tab-link\" data-toggle=\"tab\" role=\"tab\" aria-controls=\"tab-874d6c5e9186f94958d\" aria-selected=\"true\" id=\"mobile-fusion-tab-1.combustionchamber\" href=\"#tab-874d6c5e9186f94958d\"><h4 class=\"fusion-tab-heading\">1. COMBUSTION CHAMBER<\/h4><\/a><\/li><\/ul><\/div><div class=\"tab-pane fade fusion-clearfix in active\" role=\"tabpanel\" tabindex=\"0\" aria-labelledby=\"fusion-tab-1.combustionchamber\" id=\"tab-874d6c5e9186f94958d\">\n<ul>\n<li class=\"ai-optimize-15\"><strong>Combustion chamber with push grate firing\u00a0<\/strong><br \/>\nFully fireclay-lined, stoichiometrically optimised combustion chamber with primary and secondary air zones.<br \/>\nHydraulically operated push grate for burning wet, ash-containing material. Fully automatic ash removal via ash slide.<br \/>\n\u00bb Nominal output: 2000 kW with fuel M40<br \/>\n\u00bb Max. water content: M50 (up to M55 with air preheating)<\/li>\n<\/ul>\n<\/div><div class=\"nav fusion-mobile-tab-nav\"><ul class=\"nav-tabs\" role=\"tablist\"><li role=\"presentation\"><a class=\"tab-link\" data-toggle=\"tab\" role=\"tab\" aria-controls=\"tab-246bb97691b3ec6137e\" aria-selected=\"false\" tabindex=\"-1\" id=\"mobile-fusion-tab-2.fluegasrecirculation\" href=\"#tab-246bb97691b3ec6137e\"><h4 class=\"fusion-tab-heading\">2. FLUE GAS RECIRCULATION<\/h4><\/a><\/li><\/ul><\/div><div class=\"tab-pane fade fusion-clearfix\" role=\"tabpanel\" tabindex=\"0\" aria-labelledby=\"fusion-tab-2.fluegasrecirculation\" id=\"tab-246bb97691b3ec6137e\">\n<ul>\n<li class=\"ai-optimize-17\"><strong>Flue gas recirculation\u00a0<\/strong><br \/>\nreduces emissions and slag, automatically adjusts the combustion air and directs more heat to the heat exchanger \u2013 ideal for fuels with a high calorific value, low ash melting point and high nitrogen content.<\/li>\n<\/ul>\n<\/div><div class=\"nav fusion-mobile-tab-nav\"><ul class=\"nav-tabs\" role=\"tablist\"><li role=\"presentation\"><a class=\"tab-link\" data-toggle=\"tab\" role=\"tab\" aria-controls=\"tab-4330ef8f3392df8328a\" aria-selected=\"false\" tabindex=\"-1\" id=\"mobile-fusion-tab-3.automaticcompressedaircleaning\" href=\"#tab-4330ef8f3392df8328a\"><h4 class=\"fusion-tab-heading\">3. AUTOMATIC COMPRESSED AIR CLEANING<\/h4><\/a><\/li><\/ul><\/div><div class=\"tab-pane fade fusion-clearfix\" role=\"tabpanel\" tabindex=\"0\" aria-labelledby=\"fusion-tab-3.automaticcompressedaircleaning\" id=\"tab-4330ef8f3392df8328a\">\n<ul>\n<li class=\"ai-optimize-19\"><strong>Automatic compressed air cleaning<\/strong><br \/>\nAutomatic compressed air cleaning of the boiler tubes significantly reduces cleaning effort and ensures longer operating times at low exhaust gas temperatures and high boiler efficiency.<\/li>\n<\/ul>\n<\/div><div class=\"nav fusion-mobile-tab-nav\"><ul class=\"nav-tabs\" role=\"tablist\"><li role=\"presentation\"><a class=\"tab-link\" data-toggle=\"tab\" role=\"tab\" aria-controls=\"tab-98794b8bd28b1840c6d\" aria-selected=\"false\" tabindex=\"-1\" id=\"mobile-fusion-tab-4.power&amp;combustioncontrolcvp\" href=\"#tab-98794b8bd28b1840c6d\"><h4 class=\"fusion-tab-heading\">4. POWER &amp; COMBUSTION CONTROL CVP<\/h4><\/a><\/li><\/ul><\/div><div class=\"tab-pane fade fusion-clearfix\" role=\"tabpanel\" tabindex=\"0\" aria-labelledby=\"fusion-tab-4.power&amp;combustioncontrolcvp\" id=\"tab-98794b8bd28b1840c6d\">\n<ul>\n<li class=\"ai-optimize-21\"><strong>CVP power and combustion control:<\/strong><br \/>\nContinuously calculates current demand, controls material feed and air volumes continuously. Dynamic lambda-controlled secondary air, automatic negative pressure compensation and speed-controlled fans minimise power consumption and ensure optimum efficiency across the entire power range.<\/li>\n<\/ul>\n<\/div><div class=\"nav fusion-mobile-tab-nav\"><ul class=\"nav-tabs\" role=\"tablist\"><li role=\"presentation\"><a class=\"tab-link\" data-toggle=\"tab\" role=\"tab\" aria-controls=\"tab-e630d6ef2108649200a\" aria-selected=\"false\" tabindex=\"-1\" id=\"mobile-fusion-tab-5.feeding\" href=\"#tab-e630d6ef2108649200a\"><h4 class=\"fusion-tab-heading\">5. FEEDING<\/h4><\/a><\/li><\/ul><\/div><div class=\"tab-pane fade fusion-clearfix\" role=\"tabpanel\" tabindex=\"0\" aria-labelledby=\"fusion-tab-5.feeding\" id=\"tab-e630d6ef2108649200a\">\n<ul>\n<li class=\"ai-optimize-23\"><strong>Feeding<\/strong><br \/>\nFeeding by means of a solid insertion screw.<\/li>\n<\/ul>\n<\/div><div class=\"nav fusion-mobile-tab-nav\"><ul class=\"nav-tabs\" role=\"tablist\"><li role=\"presentation\"><a class=\"tab-link\" data-toggle=\"tab\" role=\"tab\" aria-controls=\"tab-2ccbaa6d3134603a5ed\" aria-selected=\"false\" tabindex=\"-1\" id=\"mobile-fusion-tab-6.optional:hilovesystem\" href=\"#tab-2ccbaa6d3134603a5ed\"><h4 class=\"fusion-tab-heading\">6. OPTIONAL: HILOVE SYSTEM<\/h4><\/a><\/li><\/ul><\/div><div class=\"tab-pane fade fusion-clearfix\" role=\"tabpanel\" tabindex=\"0\" aria-labelledby=\"fusion-tab-6.optional:hilovesystem\" id=\"tab-2ccbaa6d3134603a5ed\">\n<ul>\n<li class=\"ai-optimize-25\"><strong>OPTIONAL: The HiLoVe system<\/strong><br \/>\nserves as a bypass for the second heat exchanger pass and enables precise control of the exhaust gas temperature. In partial load operation, it prevents the exhaust gases from cooling down too much and condensation from forming in flue pipes and system components.<\/li>\n<\/ul>\n<\/div><div class=\"nav fusion-mobile-tab-nav\"><ul class=\"nav-tabs\" role=\"tablist\"><li role=\"presentation\"><a class=\"tab-link\" data-toggle=\"tab\" role=\"tab\" aria-controls=\"tab-ba54cbd1f13e3fbf502\" aria-selected=\"false\" tabindex=\"-1\" id=\"mobile-fusion-tab-7.optionalluwa-system\" href=\"#tab-ba54cbd1f13e3fbf502\"><h4 class=\"fusion-tab-heading\">7. OPTIONAL LUWA-SYSTEM<\/h4><\/a><\/li><\/ul><\/div><div class=\"tab-pane fade fusion-clearfix\" role=\"tabpanel\" tabindex=\"0\" aria-labelledby=\"fusion-tab-7.optionalluwa-system\" id=\"tab-ba54cbd1f13e3fbf502\">\n<ul>\n<li class=\"ai-optimize-27\"><strong>OPTIONAL LUWA-System<\/strong><br \/>\nThe LUWA system (air preheating) preheats the combustion air, enables the efficient use of moist fuels with a water content of up to 55% and increases heat transfer, operating efficiency and sustainability.<\/li>\n<\/ul>\n<\/div><\/div><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-5 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;\" ><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-6 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\" style=\"--awb-bg-blend:overlay;--awb-bg-size:cover;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-7 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first\" style=\"--awb-bg-blend:overlay;--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-image-element fusion-image-align-center in-legacy-container\" style=\"text-align:center;\"><div class=\"imageframe-align-center\"><span class=\" fusion-imageframe imageframe-none imageframe-1 hover-type-none\"><img decoding=\"async\" src=\"https:\/\/www.herz-energie.at\/wp-content\/uploads\/2025\/11\/3D-Visualisierung-300x169.png\" alt class=\"img-responsive\"\/><\/span><\/div><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-8 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last\" style=\"--awb-bg-blend:overlay;--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-text fusion-text-5\"><h2 class=\"ai-optimize-35\"><span style=\"color: #004f38;\">Visualisation<\/span><\/h2>\n<\/div><ul style=\"--awb-size:16px;--awb-iconcolor:#e30613;--awb-line-height:27.2px;--awb-icon-width:27.2px;--awb-icon-height:27.2px;--awb-icon-margin:11.2px;--awb-content-margin:38.4px;\" class=\"fusion-checklist fusion-checklist-2 fusion-checklist-default type-icons\"><li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa-check-circle fas\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">\n<p class=\"ai-optimize-118\">Convenient menu navigation and simple screen design<\/p>\n<\/div><\/li><li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa-check-circle fas\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">\n<p class=\"ai-optimize-37\">The visualisation depicts your system directly from the plan.<\/p>\n<\/div><\/li><li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa-check-circle fas\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">\n<p class=\"ai-optimize-121\">Customisable parameter display &amp; integrated data recording<\/p>\n<\/div><\/li><li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa-check-circle fas\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">\n<p class=\"ai-optimize-123\">Integration of the combustion chamber camera<\/p>\n<\/div><\/li><li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa-check-circle fas\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">\n<p class=\"ai-optimize-125\">Optional with QM-Holzheizwerke interface<\/p>\n<\/div><\/li><li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa-check-circle fas\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">\n<p class=\"ai-optimize-127\">Remote visualisation and remote maintenance possible with existing internet connection<\/p>\n<\/div><\/li><\/ul><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><\/p>","protected":false},"excerpt":{"rendered":"","protected":false},"author":644,"featured_media":0,"parent":24,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"100-width.php","meta":{"footnotes":""},"class_list":["post-2914","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.2 (Yoast SEO v25.2) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>HERZ BioFire Taurus 2000 - HERZ Energietechnik<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.herz-energie.at\/en\/products\/wood-chip-pellet-boiler\/herz-biofire-2000-taurus\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"HERZ BioFire Taurus 2000\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.herz-energie.at\/en\/products\/wood-chip-pellet-boiler\/herz-biofire-2000-taurus\/\" \/>\n<meta property=\"og:site_name\" content=\"HERZ Energietechnik\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/HERZ.Energietechnik\/\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-11T14:58:19+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@HERZ_Energie\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.herz-energie.at\/en\/products\/wood-chip-pellet-boiler\/herz-biofire-2000-taurus\/\",\"url\":\"https:\/\/www.herz-energie.at\/en\/products\/wood-chip-pellet-boiler\/herz-biofire-2000-taurus\/\",\"name\":\"HERZ BioFire Taurus 2000 - HERZ Energietechnik\",\"isPartOf\":{\"@id\":\"https:\/\/www.herz-energie.at\/en\/#website\"},\"datePublished\":\"2025-12-05T07:07:45+00:00\",\"dateModified\":\"2026-02-11T14:58:19+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.herz-energie.at\/en\/products\/wood-chip-pellet-boiler\/herz-biofire-2000-taurus\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.herz-energie.at\/en\/products\/wood-chip-pellet-boiler\/herz-biofire-2000-taurus\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.herz-energie.at\/en\/products\/wood-chip-pellet-boiler\/herz-biofire-2000-taurus\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.herz-energie.at\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/www.herz-energie.at\/en\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Wood chip-\/ pellet boiler\",\"item\":\"https:\/\/www.herz-energie.at\/en\/products\/wood-chip-pellet-boiler\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"HERZ BioFire Taurus 2000\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.herz-energie.at\/en\/#website\",\"url\":\"https:\/\/www.herz-energie.at\/en\/\",\"name\":\"HERZ Energietechnik\",\"description\":\"The specialist for renewable energy systems\",\"publisher\":{\"@id\":\"https:\/\/www.herz-energie.at\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.herz-energie.at\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.herz-energie.at\/en\/#organization\",\"name\":\"HERZ Energietechnik\",\"url\":\"https:\/\/www.herz-energie.at\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.herz-energie.at\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.herz-energie.at\/en\/wp-content\/uploads\/sites\/2\/2016\/01\/HERZ-Energietechnik_logo1x1.jpg\",\"contentUrl\":\"https:\/\/www.herz-energie.at\/en\/wp-content\/uploads\/sites\/2\/2016\/01\/HERZ-Energietechnik_logo1x1.jpg\",\"width\":218,\"height\":76,\"caption\":\"HERZ Energietechnik\"},\"image\":{\"@id\":\"https:\/\/www.herz-energie.at\/en\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/HERZ.Energietechnik\/\",\"https:\/\/x.com\/HERZ_Energie\",\"https:\/\/at.linkedin.com\/company\/herz-energietechnik-gmbh\",\"https:\/\/www.youtube.com\/user\/woHEIZUNGdaHERZ\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"HERZ BioFire Taurus 2000 - HERZ Energietechnik","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.herz-energie.at\/en\/products\/wood-chip-pellet-boiler\/herz-biofire-2000-taurus\/","og_locale":"en_US","og_type":"article","og_title":"HERZ BioFire Taurus 2000","og_url":"https:\/\/www.herz-energie.at\/en\/products\/wood-chip-pellet-boiler\/herz-biofire-2000-taurus\/","og_site_name":"HERZ Energietechnik","article_publisher":"https:\/\/www.facebook.com\/HERZ.Energietechnik\/","article_modified_time":"2026-02-11T14:58:19+00:00","twitter_card":"summary_large_image","twitter_site":"@HERZ_Energie","twitter_misc":{"Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.herz-energie.at\/en\/products\/wood-chip-pellet-boiler\/herz-biofire-2000-taurus\/","url":"https:\/\/www.herz-energie.at\/en\/products\/wood-chip-pellet-boiler\/herz-biofire-2000-taurus\/","name":"HERZ BioFire Taurus 2000 - HERZ Energietechnik","isPartOf":{"@id":"https:\/\/www.herz-energie.at\/en\/#website"},"datePublished":"2025-12-05T07:07:45+00:00","dateModified":"2026-02-11T14:58:19+00:00","breadcrumb":{"@id":"https:\/\/www.herz-energie.at\/en\/products\/wood-chip-pellet-boiler\/herz-biofire-2000-taurus\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.herz-energie.at\/en\/products\/wood-chip-pellet-boiler\/herz-biofire-2000-taurus\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.herz-energie.at\/en\/products\/wood-chip-pellet-boiler\/herz-biofire-2000-taurus\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.herz-energie.at\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.herz-energie.at\/en\/products\/"},{"@type":"ListItem","position":3,"name":"Wood chip-\/ pellet boiler","item":"https:\/\/www.herz-energie.at\/en\/products\/wood-chip-pellet-boiler\/"},{"@type":"ListItem","position":4,"name":"HERZ BioFire Taurus 2000"}]},{"@type":"WebSite","@id":"https:\/\/www.herz-energie.at\/en\/#website","url":"https:\/\/www.herz-energie.at\/en\/","name":"HERZ Energietechnik","description":"The specialist for renewable energy systems","publisher":{"@id":"https:\/\/www.herz-energie.at\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.herz-energie.at\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.herz-energie.at\/en\/#organization","name":"HERZ Energietechnik","url":"https:\/\/www.herz-energie.at\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.herz-energie.at\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.herz-energie.at\/en\/wp-content\/uploads\/sites\/2\/2016\/01\/HERZ-Energietechnik_logo1x1.jpg","contentUrl":"https:\/\/www.herz-energie.at\/en\/wp-content\/uploads\/sites\/2\/2016\/01\/HERZ-Energietechnik_logo1x1.jpg","width":218,"height":76,"caption":"HERZ Energietechnik"},"image":{"@id":"https:\/\/www.herz-energie.at\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/HERZ.Energietechnik\/","https:\/\/x.com\/HERZ_Energie","https:\/\/at.linkedin.com\/company\/herz-energietechnik-gmbh","https:\/\/www.youtube.com\/user\/woHEIZUNGdaHERZ"]}]}},"_links":{"self":[{"href":"http:\/\/www.herz-energie.at\/en\/wp-json\/wp\/v2\/pages\/2914","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.herz-energie.at\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/www.herz-energie.at\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/www.herz-energie.at\/en\/wp-json\/wp\/v2\/users\/644"}],"replies":[{"embeddable":true,"href":"http:\/\/www.herz-energie.at\/en\/wp-json\/wp\/v2\/comments?post=2914"}],"version-history":[{"count":8,"href":"http:\/\/www.herz-energie.at\/en\/wp-json\/wp\/v2\/pages\/2914\/revisions"}],"predecessor-version":[{"id":3046,"href":"http:\/\/www.herz-energie.at\/en\/wp-json\/wp\/v2\/pages\/2914\/revisions\/3046"}],"up":[{"embeddable":true,"href":"http:\/\/www.herz-energie.at\/en\/wp-json\/wp\/v2\/pages\/24"}],"wp:attachment":[{"href":"http:\/\/www.herz-energie.at\/en\/wp-json\/wp\/v2\/media?parent=2914"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}